大加振力风冷式大型振动试验装置(74kN)开始销售

IMV CORPORATION’s latest addition to the A-series range has already achieved significant success with many blue chip companies taking advantage of this industry leading system.
The world leading A-series class A74 has a displacement of 76.2 mm p-p and a shock velocity rating of 3.5 m/s.
This makes the A74 capable of a 100 g, 11 ms shock pulse with an exceptional force rating of 74 kN sine and random.
The A74 is available with IMV’s award winning eco-technology.

Specifications

  System Model A74/EM8HM A74/EM10HM
  Frequency Range(Hz) 0–2600*3 0–2600*3
System
Specifications
Rated
Force
Sine(kN) 74 74
Random(kN rms)*1 74 74
Shock(kN) 148(120) 180(160)
Maximum
Acc.
Sine(m/s2) 1000 1000
Random(m/s2 rms) 630 630
Shock(m/s2 peak) 2000 2432
Maximum
Vel.
Sine(m/s) 2.0 2.0
Shock(m/s peak) 2.5(3.5) 2.5(3.5)
Maximum
Disp.
Sine(mmp-p) 76.2 76.2
Maximum Travel(mmp-p) 82 82
Maximum Load(kg) 1000 1000
Power Requirements(kVA)*2 100 100
Vibration
Generator
Model A74 A74
Armature Mass(Kg) 74 74
Armature Diameter(φmm) 446 446
Allowable Eccentric Moment(N・m) 1550 1550
Dimensions(mm) WxHxD 1310x1253x1040 1310x1253x1040
Shaker Body Diameter(mm) 925 925
Mass(kg) 3500 3500
Power
Amplifier
Model EM8HM-A74 EM10HM-A74
Maximum Output(kVA) 100 100
Dimensions(mm) WxHxD 1740*4x1950x850 1740x1950x850
Mass(kg) 1800*5 1850
Blower Dimensions(mm) WxHxD 1462x2800x930 1462x2800x930
Mass(kg) 536 536

*1) Force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements.
*2) Power supply: 3-phase 200/220 V, 50/60Hz or 3-phase 380/400/415/440 V, 50/60 Hz. A transformer is required for other supply voltages.If other voltage is required, delivery date needs extra one month.
*3) Above 2000 Hz, the force rolls-off at a rate of -12 dB/oct.
*4)Width of EM8HM power amplifier is 1160 mm when the power supply is 200-240 V.
*5)Mass of EM8HM power amplifier is 1500 kg when the power supply is 200-240 V.
* The specification shows the maximum system performance. For long-duration tests, de-rating by up to 70 % must be applied. Continuous use at maximum levels may cause failure.
* In the case of Random vibration test, please set the test definition of the peak value of acceleration waveform to be operated less than the maximum acceleration of Shock.
* Frequency range values vary according to sensor and vibration controller.